3 Phase kWhmeter direct 125A 6M S0 MID ECP310D

EAN
3250612231409
Packaging
1 Piece

Technical properties

Architecture
  • Number of poles
    4 P
  • Type of pole
    3P+N
  • Fixing mode
    DIN rail type O (symmetrical)
Functions
  • Precision class
    B
  • Tarif type
    T1...T2 (230 V AC) / -
Configuration
  • Number of modules
    6
Compatibility
  • Suitable for
    Purchase / supply
Main electrical features
  • Rated operational voltage Ue
    92 / 480 V
  • Type of supply voltage
    AC
  • Frequency
    50 Hz
Voltage
  • Max operating voltage
    300 V
  • Rated impulse withstand voltage
    6 kV
Electric current
  • Minimum operating current
    0.02 A
  • Operating current
    0.02 / 125 A
  • Rated current
    125 A
  • Reference current
    5 A
  • Max. measurement circuit current
    125 A
Dimensions
  • Depth of installed product
    60 mm
  • Height of installed product
    92 mm
  • Width of installed product
    107 mm
Power
  • Power consumed
    2 VA
  • Total power loss under IN
    0.6 W
  • Plage Impulsion/KWh
    1 / 200 Imp/kWh
Electrical specifications
  • Type of pulse generator
    électrical
Measurement
  • Frequency measuring range
    45 to 65 Hz
  • Type of measuring instrument
    electronical
  • Principle of measurement
    Direct measurement
Power supply
  • Supply voltage
    400 V ± 20%
Installation, mounting
  • Tightening torque
    5Nm
  • Mounting type
    din-Rail
Connection
  • Wire cross section of metering entrance wire
    50 mm²
  • Wire cross section of metering outgoing wire
    50 mm²
Settings
  • Value of a pulse
    100 Wh
Equipment
  • Type of display
    retro illuminated display
  • Tariff model of kilowatt-hour meter
    Externa
  • Type of counter
    4 wires counter
Use
  • Pulse duration
    30 / 100 ms
Standards
  • Standard text
    EN 50470-1 / 3, IEC 62053-21 / 23, IEC 61557-12
  • Certified product
    MID (Measuring Instruments Directive)
  • European directive WEEE
    concerned
Safety
  • Protection index IP
    IP20
  • Protection class
    isol.class II
Use conditions
  • Operating temperature
    -25…55 °C
  • Degree of pollution according to IEC 60664 / IEC 60947-2
    2
  • Altitude
    2000 m
  • Storage/transport temperature
    -25…70 °C

Downloads

  • Product image

    Image ECP310D  | Hager Australia

    Product Image ECP310D

  • ProductNotice

    Image Instruction manuals for ECP310D  | Hager Australia

    Instruction manuals for ECP310D

    PDF
    1 MB
  • User brochure

    Image Energy Meters Brochure  | Hager Australia

    Energy Meters Brochure

    PDF
    15 MB
  • MarketingTechnicalBrochure

    Image Energy Meters Specifications and Technical Guide  | Hager Australia

    Energy Meters Specifications and Technical Guide

    PDF
    1 MB
  • ProductECDeclaration

    Image Declaration  | Hager Australia

    Declaration

    PDF
    245 KB
    Image Declaration  | Hager Australia

    Declaration

    PDF
    58 KB
  • ProductEnvironmentProfile

    Image Product environmental profile for ECP310D  | Hager Australia

    Product environmental profile for ECP310D

    PDF
    427 KB
More documentation