HA457

HA457 Load break switch 4P 400A

HA457

Load break switch 4P 400A

Cat. Ref.:HA457
pc.
EAN No.:

3250613114572

Pack Qty.:1 pc.
ex. GST*:916.41 $ / pc.
inc. GST*:1,008.05 $ / pc.
Price Group:22100
Technical Characteristics
Type of order:Long thumb-grip
Type of case:Fixed built-in
Number of poles:4 P
Type of pole:4 P
Reversing switch:no
Motor drive integrated:no
Rated operational voltage Ue:380/415 V
Rated insulation voltage:1000 V
Rated impulse withstand voltage:8000 V
Rated operational current in AC21 category A:400 A
Rated operational current in AC21category B:400 A
Acceptable current rating with AC22 category A:400 A
Acceptable current rating with AC22 category B:400 A
Rated operational current in AC23 category A:400 A
Acceptable current rating with AC23 category B:400 A
Cut off current:30 kA
Short-circuit current with gI-gG fuses:50 kA
Rated short-time withstand current Icw:9 kA
Rated short-time withstand current 1s:9 kA
Nominal power under 440/500, 50Hz:140 kW
Nominal power under 660 V, 50 Hz:90 kW
Active power under 380/415 V, 50 Hz:132 kW
Contact rating with 400 V in AC1:263 kW
Power loss per pole at In:14,4 W
Total power loss under IN:57,6 W
Interlockable:yes
Fixation type:Back plate monting
Connection cross-sect. rigid cable:1x240mm²
Type of connection:Terminal
Width available for insulation connection:185 mm²
Motor drive optional:no
Standard text:IEC 60947-3
European directive WEEE:concerned
Protection index IP:IP00
  • HA457
    HA457 Load break switch 4P 400A
    HA457
  • HA457 Load break switch 4P 400A
Visitors who viewed this product also viewed the following products
HA364 Load break switch 3P 1600A
Load break switch 3P 1600A
HA458 Load break switch 4P 630A
Load break switch 4P 630A
HA362 Load break switch 3P 1250A
Load break switch 3P 1250A
HXC003H SHT trip Release 100-120VAC(h250...1000)
SHT trip Release 100-120VAC(h250...1000)
HXC005H SHT trip Release 380-450VAC(h250...1000)
SHT trip Release 380-450VAC(h250...1000)
HXC024H Alarm contact 1NO+1NC 230V(h250...1600)
Alarm contact 1NO+1NC 230V(h250...1600)
HXE011H UVR 24VDC (h800-h1000-h1600)
UVR 24VDC (h800-h1000-h1600)
HA360 Load break switch 3P 800A
Load break switch 3P 800A
HXE013H UVR 110-120VAC (h800-h1000-h1600)
UVR 110-120VAC (h800-h1000-h1600)
HA358 Load break switch 3P 630A
Load break switch 3P 630A
HXE014H UVR 220-240VAC (h800-h1000-h1600)
UVR 220-240VAC (h800-h1000-h1600)
*All data is subject to errors and technical modifications. All prices are recommended retail prices.