HNC041H

HNC041H MCCB h250 4P 50kA 40A LSI

HNC041H

MCCB h250 4P 50kA 40A LSI

Cat. Ref.:HNC041H
pc.
EAN No.:

3250613340582

Pack Qty.:1 pc.
ex. GST*:2,477.65 $ / pc.
inc. GST*:2,725.42 $ / pc.
Price Group:15230
Technical Characteristics
Type of order:Toggle
Type of case:Fixed built-in
Number of poles:4 P
Type of pole:4P4D N:0;50;100%
Complete device with protection unit:yes
Trip Unit:LSI
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/690 V
Rated insulation voltage:800 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:50 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Breaking capacity on 1 pole with 230 V NF 60947-2:60 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:50 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:50 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:7,5 kA
Thermal protection nob setting xIN:0,4/0,5/0,63/0,8/0,9/0,95/1
Thermal setting current on neutral pole:0/0,5/1 In
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:0,6 W
Power loss per pole at 0.63*In:0,3 W
Power loss per pole at 0.8*In:0,4 W
Total power loss under IN:1,9 W
Total power loss at 0.63*In:0,7 W
Total power loss at 0.8*In:1,2 W
Tripmode:LSI
Thermal protection trip time:5/8/11/21 ms
Time of response when opening:10 ms
Magnetic trip delay time:100 to 200 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:12Nm
DIN rail mounting with optional adaptator:no
Connection cross-sect. rigid cable:35 / 185mm²
Connection cross-sect. flexible conductor:35 / 150mm²
Connection:Front connection
Type of connection:Terminal
Magnetic protection nob setting xIN:2,5/5/10
Setting type In or Ith:IrTh
Range of the magnetic adjustment:224/280/350/448/504/532/560 A
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Altitude:2000 m
Storage temperature:-35 to 70 °C
Air humidity protection:for all climates
  • HNC041H
    HNC041H MCCB h250 4P 50kA 40A LSI
    HNC041H
  • HNC041H MCCB h250 4P 50kA 40A LSI
Visitors who viewed this product also viewed the following products
HNC126H MCCB h250 4P 50kA 125A LSI
MCCB h250 4P 50kA 125A LSI
HNC040H MCCB h250 3P 50kA 40A LSI
MCCB h250 3P 50kA 40A LSI
HNC250H MCCB h250 3P 50kA 250A LSI
MCCB h250 3P 50kA 250A LSI
HNC251H MCCB h250 4P 50kA 250A LSI
MCCB h250 4P 50kA 250A LSI
HEC251H MCCB h250 4P 70kA 250A LSI
MCCB h250 4P 70kA 250A LSI
HXC001H Shunt trip Release 24V DC(h250...1000)
Shunt trip Release 24V DC(h250...1000)
HXC002H Shunt trip Release 48V DC(h250...1000)
Shunt trip Release 48V DC(h250...1000)
HXC003H SHT trip Release 100-120VAC(h250...1000)
SHT trip Release 100-120VAC(h250...1000)
HEC250H MCCB h250 3P 70kA 250A LSI
MCCB h250 3P 70kA 250A LSI
HXC004H SHT trip Release 200-240VAC(h250...1000)
SHT trip Release 200-240VAC(h250...1000)
*All data is subject to errors and technical modifications. All prices are recommended retail prices.