  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

HHA026U

HHA026U MCCB h3 x160 TM 4x25A 25kA

Similar image
(Picture shows HHA161U)

MCCB h3 x160 TM 4x25A 25kA

Cat. Ref.:HHA026U
pc.
EAN No.:

3250613131074

Pack Qty.:1 pc.
ex. GST*:638.09 $ / pc.
inc. GST*:701.90 $ / pc.
Price Group:15150
Technical Characteristics
Number of protected poles:4
Number of poles:4 P
Type of pole:4P4D
Trip Unit:TM A/F
Compatible with DIN rail mounting:no
Motor drive integrated:no
Rated operational voltage Ue:220 / 415 V
Frequency:50/60 Hz
Rated insulation voltage:690 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:25 A
Thermal protection nob setting xIN:0,63 / 0,8 / 1
Rating current 10°C according to IEC 60947:29,5 A
Rating current 150°C according to IEC 60947:29 A
Rating current 20°C according to IEC 60947:28,4 A
Rating current 25°C according to IEC 60947:27,9 A
Rating current 30°C according to IEC 60947:27,3 A
Rating current 35°C according to IEC 60947:26,7 A
Rating current 40°C according to IEC 60947:26,2 A
Rating current 45°C according to IEC 60947:25,6 A
Rating current 50°C according to IEC 60947:25 A
Rating current 55°C according to IEC 60947:24,3 A
Rating current 60°C according to IEC 60947:23,7 A
Rating current 65°C according to IEC 60947:23 A
Rating current 70°C according to IEC 60947:22,3 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:20 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:25 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:25 kA
Range of the thermal adjustment:16 / 20 / 25 A
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:25 kA
Frequency:50 to 60 Hz
Power loss per pole at 0.63*In:1,9 W
Power loss per pole at 0.8*In:2,9 W
Total power loss at 0.63*In:5,6 W
Total power loss at 0.8*In:8,7 W
Total power loss under IN:13,7 W
Power loss per pole at In:4,6 W
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Depth of installed product:68 mm
Height of installed product:130 mm
Width of installed product:100 mm
Critical distance switching emission/earthed part bottom:40 mm
Critical distance switching emission/earthed part left:50 mm
Critical distance switching emission/earthed part right:50 mm
Critical distance switching emission/earthed part top:40 mm
Critical distance switching emission/insulated plate:30 mm
Critical distance switching emission/live part:50 mm
Type of connection:with screw
Range of the magnetic adjustment:600 A
Can be accessorized:yes
Standard text:IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP4X
Degree of pollution according to IEC 60664 / IEC 60947-2:3
Altitude:2000 m
Temperature of calibration:50 °C
  • HHA026U
    HHA026U MCCB h3 x160 TM 4x25A 25kA
    Similar image
    (Picture shows HHA161U)
  • HHA026U MCCB h3 x160 TM 4x25A 25kA
*All data is subject to errors and technical modifications. All prices are recommended retail prices.