HHA064U

HHA064U MCCB h3 x160 TM 4x63A 25kA

Similar image
(Picture shows HHA161U)

MCCB h3 x160 TM 4x63A 25kA

Cat. Ref.:HHA064U
pc.
EAN No.:

3250613131098

Pack Qty.:1 pc.
ex. GST*:654.05 $ / pc.
inc. GST*:719.46 $ / pc.
Price Group:15150
Technical Characteristics
Number of protected poles:4
Number of poles:4 P
Type of pole:4P4D
Trip Unit:TM A/F
Compatible with DIN rail mounting:no
Motor drive integrated:no
Rated operational voltage Ue:220 / 415 V
Frequency:50/60 Hz
Rated insulation voltage:690 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:63 A
Thermal protection nob setting xIN:0,63 / 0,8 / 1
Rating current 10°C according to IEC 60947:71,7 A
Rating current 150°C according to IEC 60947:70,7 A
Rating current 20°C according to IEC 60947:69,6 A
Rating current 25°C according to IEC 60947:68,6 A
Rating current 30°C according to IEC 60947:67,5 A
Rating current 35°C according to IEC 60947:66,4 A
Rating current 40°C according to IEC 60947:65,3 A
Rating current 45°C according to IEC 60947:64,1 A
Rating current 50°C according to IEC 60947:63 A
Rating current 55°C according to IEC 60947:61,8 A
Rating current 60°C according to IEC 60947:60,6 A
Rating current 65°C according to IEC 60947:59,3 A
Rating current 70°C according to IEC 60947:58,1 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:20 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:25 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:25 kA
Range of the thermal adjustment:40 / 50 / 63 A
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:25 kA
Frequency:50 to 60 Hz
Power loss per pole at 0.63*In:4 W
Power loss per pole at 0.8*In:6,3 W
Total power loss at 0.63*In:12,1 W
Total power loss at 0.8*In:18,9 W
Total power loss under IN:30 W
Power loss per pole at In:10 W
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Depth of installed product:68 mm
Height of installed product:130 mm
Width of installed product:100 mm
Critical distance switching emission/earthed part bottom:40 mm
Critical distance switching emission/earthed part left:50 mm
Critical distance switching emission/earthed part right:50 mm
Critical distance switching emission/earthed part top:40 mm
Critical distance switching emission/insulated plate:30 mm
Critical distance switching emission/live part:50 mm
Type of connection:with screw
Range of the magnetic adjustment:1000 A
Can be accessorized:yes
Standard text:IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP4X
Degree of pollution according to IEC 60664 / IEC 60947-2:3
Altitude:2000 m
Temperature of calibration:50 °C