  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

HHA080U

HHA080U MCCB h3 x160 TM 3x80A 25kA

Similar image
(Picture shows HHA125U)
HHA080U MCCB h3 x160 TM 3x80A 25kA
HHA080U MCCB h3 x160 TM 3x80A 25kA

MCCB h3 x160 TM 3x80A 25kA

Cat. Ref.:HHA080U
pc.
EAN No.:

3250613130763

Pack Qty.:1 pc.
ex. GST*:483.92 $ / pc.
inc. GST*:532.31 $ / pc.
Price Group:15150
Technical Characteristics
Neutral position:without neutral
Number of protected poles:3
Number of poles:3 P
Type of pole:3P3D
Trip Unit:TM A/F
Concurrently switching N-neutral:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Rated operational voltage Ue:220 / 415 V
Frequency:50/60 Hz
Rated insulation voltage:690 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated current:80 A
Thermal protection nob setting xIN:0,63 / 0,8 / 1
Rating current 10°C according to IEC 60947:93,2 A
Rating current 150°C according to IEC 60947:91,6 A
Rating current 20°C according to IEC 60947:90,1 A
Rating current 25°C according to IEC 60947:88,5 A
Rating current 30°C according to IEC 60947:86,8 A
Rating current 35°C according to IEC 60947:85,2 A
Rating current 40°C according to IEC 60947:83,5 A
Rating current 45°C according to IEC 60947:81,7 A
Rating current 50°C according to IEC 60947:80 A
Rating current 55°C according to IEC 60947:78,1 A
Rating current 60°C according to IEC 60947:76,3 A
Rating current 65°C according to IEC 60947:74,4 A
Rating current 70°C according to IEC 60947:72,4 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:25 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:20 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:25 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:25 kA
Range of the thermal adjustment:50 / 63 / 80 A
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:25 kA
Frequency:50 to 60 Hz
Power loss per pole at 0.63*In:4,2 W
Power loss per pole at 0.8*In:6,6 W
Total power loss at 0.63*In:12,5 W
Total power loss at 0.8*In:19,9 W
Total power loss under IN:32,1 W
Power loss per pole at In:10,7 W
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Depth of installed product:68 mm
Height of installed product:130 mm
Width of installed product:75 mm
Critical distance switching emission/earthed part bottom:40 mm
Critical distance switching emission/earthed part left:50 mm
Critical distance switching emission/earthed part right:50 mm
Critical distance switching emission/earthed part top:40 mm
Critical distance switching emission/insulated plate:30 mm
Critical distance switching emission/live part:50 mm
Type of connection:with screw
Range of the magnetic adjustment:1000 A
Can be accessorized:yes
Standard text:IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP4X
Degree of pollution according to IEC 60664 / IEC 60947-2:3
Altitude:2000 m
Temperature of calibration:50 °C
  • HHA080U
    HHA080U MCCB h3 x160 TM 3x80A 25kA
    Similar image
    (Picture shows HHA125U)
  • HHA080U
    HHA080U MCCB h3 x160 TM 3x80A 25kA
    HHA080U
  • HHA080U MCCB h3 x160 TM 3x80A 25kA
  • HHA080U MCCB h3 x160 TM 3x80A 25kA
*All data is subject to errors and technical modifications. All prices are recommended retail prices.