  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

HHA123Z

HHA123Z MCCB X160 1P 25kA 125A

HHA123Z

MCCB X160 1P 25kA 125A

Cat. Ref.:HHA123Z
pc.
EAN No.:

3250613136031

Pack Qty.:1 pc.
ex. GST*:388.57 $ / pc.
inc. GST*:427.43 $ / pc.
Price Group:15150
Technical Characteristics
Type of order:Toggle
Number of poles:1 P
Type of pole:1P1D
Complete device with protection unit:yes
Trip Unit:TM F/F
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/240 V
Rated insulation voltage:690 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:25 kA
Rated service breaking capacity Ics AC according IEC 60947-2:80 %
Breaking capacity on 1 pole with 230 V NF 60947-2:21 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:25 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:35 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:25 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:20 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:4 kA
Thermal protection nob setting xIN:1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:11,7 W
Total power loss under IN:11,7 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:6Nm
DIN rail mounting with optional adaptator:yes
Connection cross-sect. rigid cable:4 / 95mm²
Connection cross-sect. flexible conductor:4 / 70mm²
Connection:Front connection
Type of connection:with screw
Setting type In or Ith:IN
Range of the magnetic adjustment:1500 A
Motor drive optional:no
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Altitude:2000 m
Air humidity protection:for all climates
  • HHA123Z
    HHA123Z MCCB X160 1P 25kA 125A
    HHA123Z
  • HHA123Z MCCB X160 1P 25kA 125A
Visitors who viewed this product also viewed the following products
HHA014Z MCCB X160 1P 25kA 16A
MCCB X160 1P 25kA 16A
*All data is subject to errors and technical modifications. All prices are recommended retail prices.