HNA160U

HNA160U MCCB h3 x160 TM 3x160A 40kA

HNA160U

MCCB h3 x160 TM 3x160A 40kA

Cat. Ref.:HNA160U
pc.
EAN No.:

3250613130589

Pack Qty.:1 pc.
ex. GST*:1,038.33 $ / pc.
inc. GST*:1,142.16 $ / pc.
Price Group:15150
Technical Characteristics
Neutral position:without neutral
Number of protected poles:3
Number of poles:3 P
Type of pole:3P3D
Trip Unit:TM A/F
Concurrently switching N-neutral:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Rated operational voltage Ue:220 / 415 V
Frequency:50/60 Hz
Rated insulation voltage:690 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:160 A
Thermal protection nob setting xIN:0,63 / 0,8 / 1
Rating current 10°C according to IEC 60947:188,5 A
Rating current 150°C according to IEC 60947:185,2 A
Rating current 20°C according to IEC 60947:181,8 A
Rating current 25°C according to IEC 60947:178,3 A
Rating current 30°C according to IEC 60947:174,8 A
Rating current 35°C according to IEC 60947:171,2 A
Rating current 40°C according to IEC 60947:167,5 A
Rating current 45°C according to IEC 60947:163,8 A
Rating current 50°C according to IEC 60947:160 A
Rating current 55°C according to IEC 60947:156 A
Rating current 60°C according to IEC 60947:152 A
Rating current 65°C according to IEC 60947:147,8 A
Rating current 70°C according to IEC 60947:143,6 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:40 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:40 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:40 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:20 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:20 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:40 kA
Range of the thermal adjustment:100 / 125 / 160 A
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:40 kA
Frequency:50 to 60 Hz
Power loss per pole at 0.63*In:5,7 W
Power loss per pole at 0.8*In:8,9 W
Total power loss at 0.63*In:17,1 W
Total power loss at 0.8*In:26,7 W
Total power loss under IN:43,8 W
Power loss per pole at In:14,6 W
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Depth of installed product:68 mm
Height of installed product:130 mm
Width of installed product:75 mm
Critical distance switching emission/earthed part bottom:40 mm
Critical distance switching emission/earthed part left:50 mm
Critical distance switching emission/earthed part right:50 mm
Critical distance switching emission/earthed part top:40 mm
Critical distance switching emission/insulated plate:30 mm
Critical distance switching emission/live part:50 mm
Type of connection:with screw
Range of the magnetic adjustment:1600 A
Can be accessorized:yes
Standard text:IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP4X
Degree of pollution according to IEC 60664 / IEC 60947-2:3
Altitude:2000 m
Temperature of calibration:50 °C