HNB160U

HNB160U MCCB X250 3P 40kA 160A TM

HNB160U

MCCB X250 3P 40kA 160A TM

Cat. Ref.:HNB160U
pc.
EAN No.:

3250613347659

Pack Qty.:1 pc.
ex. GST*:1,621.31 $ / pc.
inc. GST*:1,783.44 $ / pc.
Price Group:15225
Technical Characteristics
Type of order:Toggle
Type of case:Fixed built-in
Number of poles:3 P
Type of pole:3P3D
Complete device with protection unit:yes
Trip Unit:TM A/A
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/415 V
Rated insulation voltage:800 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:40 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Breaking capacity on 1 pole with 230 V NF 60947-2:51 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:4 kA
Thermal protection nob setting xIN:0,63/0,8/1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:10,9 W
Power loss per pole at 0.63*In:4,3 W
Power loss per pole at 0.8*In:6,6 W
Total power loss under IN:32,6 W
Total power loss at 0.63*In:12,7 W
Total power loss at 0.8*In:19,9 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:12Nm
DIN rail mounting with optional adaptator:yes
Connection cross-sect. rigid cable:35 / 185mm²
Connection cross-sect. flexible conductor:35 / 150mm²
Connection:Front connection
Type of connection:Terminal
Magnetic protection nob setting xIN:6/8/10/13
Setting type In or Ith:IN
Range of the magnetic adjustment:960/1280/1600/2080 A
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:not concerned
Protection index IP:IP4X
Altitude:2000 m
Storage temperature:-35 to 70 °C
Air humidity protection:for all climates
  • HNB160U
    HNB160U MCCB X250 3P 40kA 160A TM
    HNB160U
  • HNB160U MCCB X250 3P 40kA 160A TM
Visitors who viewed this product also viewed the following products
HNB200U MCCB X250 3P 40kA 200A TM
MCCB X250 3P 40kA 200A TM
HNB161U MCCB X250 4P 40kA 160A TM
MCCB X250 4P 40kA 160A TM
HYA033H DIN Rail adaptator x160 3P/4P
DIN Rail adaptator x160 3P/4P
HYA028H Terminal cover for collar term. x160 4P
Terminal cover for collar term. x160 4P
MCCB X250 4P 40kA 200A TM
HNB250U MCCB X250 3P 40kA 250A TM
MCCB X250 3P 40kA 250A TM
HYA027H Terminal cover for collar term. x160 3P
Terminal cover for collar term. x160 3P
HHA160U MCCB X160 3P 25kA 160A
MCCB X160 3P 25kA 160A
*All data is subject to errors and technical modifications. All prices are recommended retail prices.