HNB250U

HNB250U MCCB X250 3P 40kA 250A TM

Similar image
(Picture shows HNB160U)
HNB250U MCCB X250 3P 40kA 250A TM
HNB250U MCCB X250 3P 40kA 250A TM

MCCB X250 3P 40kA 250A TM

Cat. Ref.:HNB250U
pc.
EAN No.:

3250613347673

Pack Qty.:1 pc.
ex. GST*:1,855.49 $ / pc.
inc. GST*:2,041.04 $ / pc.
Price Group:15225
Technical Characteristics
Type of order:Toggle
Type of case:Fixed built-in
Number of poles:3 P
Type of pole:3P3D
Complete device with protection unit:yes
Trip Unit:TM A/A
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/415 V
Rated insulation voltage:800 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:40 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Breaking capacity on 1 pole with 230 V NF 60947-2:51 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:4 kA
Thermal protection nob setting xIN:0,63/0,8/1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:16 W
Power loss per pole at 0.63*In:6,6 W
Power loss per pole at 0.8*In:10,2 W
Total power loss under IN:48 W
Total power loss at 0.63*In:19,7 W
Total power loss at 0.8*In:30,7 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:12Nm
DIN rail mounting with optional adaptator:yes
Connection cross-sect. rigid cable:35 / 185mm²
Connection cross-sect. flexible conductor:35 / 150mm²
Connection:Front connection
Type of connection:Terminal
Magnetic protection nob setting xIN:5/7/9/11
Setting type In or Ith:IN
Range of the magnetic adjustment:1250/1750/2250/2750 A
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Altitude:2000 m
Storage temperature:-35 to 70 °C
Air humidity protection:for all climates
  • HNB250U
    HNB250U MCCB X250 3P 40kA 250A TM
    Similar image
    (Picture shows HNB160U)
  • HNB250U
    HNB250U MCCB X250 3P 40kA 250A TM
    HNB250U
  • HNB250U MCCB X250 3P 40kA 250A TM
  • HNB250U MCCB X250 3P 40kA 250A TM
Visitors who viewed this product also viewed the following products
MCCB X250 4P 40kA 200A TM
MCCB X250 4P 40kA 250A TM
HNB200U MCCB X250 3P 40kA 200A TM
MCCB X250 3P 40kA 200A TM
HXA001H Shunt trip 24V DC (x160-P160-x250-P250)
Shunt trip 24V DC (x160-P160-x250-P250)
HXA002H Shunt trip 48V DC (x160-P160-x250-P250)
Shunt trip 48V DC (x160-P160-x250-P250)
HXA003H SHT 100-120V AC (x160-P160-x250-P250)
SHT 100-120V AC (x160-P160-x250-P250)
HXA004H SHT 200-240V AC (x160-P160-x250-P250)
SHT 200-240V AC (x160-P160-x250-P250)
HXA005H SHT 380-450V AC (x160-P160-x250-P250)
SHT 380-450V AC (x160-P160-x250-P250)
HNB161U MCCB X250 4P 40kA 160A TM
MCCB X250 4P 40kA 160A TM
HNB160U MCCB X250 3P 40kA 160A TM
MCCB X250 3P 40kA 160A TM
HXA013H UVR 100-120V AC (x160-P160-x250-P250)
UVR 100-120V AC (x160-P160-x250-P250)
HXA014H UVR 200-240V AC (x160-P160-x250-P250)
UVR 200-240V AC (x160-P160-x250-P250)
*All data is subject to errors and technical modifications. All prices are recommended retail prices.