•  
  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

HNB250U

HNB250U MCCB X250 3P 40kA 250A TM

Similar image
(Picture shows HNB160U)
HNB250U MCCB X250 3P 40kA 250A TM
HNB250U MCCB X250 3P 40kA 250A TM

MCCB X250 3P 40kA 250A TM

Cat. Ref.:HNB250U
pc.
EAN No.:

3250613347673

Pack Qty.:1 pc.
ex. GST*:1,949.38 $ / pc.
inc. GST*:2,144.32 $ / pc.
Price Group:15225
Technical Characteristics
Type of order:Toggle
Number of poles:3 P
Type of pole:3P3D
Complete device with protection unit:yes
Trip Unit:TM A/A
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Rated operational voltage Ue:220 / 415 V
Frequency:50/60 Hz
Rated insulation voltage:800 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:250 A
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:4 kA
Thermal protection nob setting xIN:0,63 / 0,8 / 1
Breaking capacity on 1 pole for IT 230V NF 60947-2:51 kA
Breaking capacity on 1 pole for IT 400V NF 60947-2:9 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:30 kA
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Total power loss under IN:48 W
Power loss per pole at In:16 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:12Nm
DIN rail mounting with optional adaptator:yes
Connection cross-sect. flexible conductor:35 / 150mm²
Connection cross-sect. rigid cable:35 / 185mm²
Connection:Front connection
Type of connection:Terminal
Range of the magnetic adjustment:1250 / 1750 / 2250 / 2750 A
Magnetic protection nob setting xIN:5 / 7 / 9 / 11
Setting type In or Ith:IN
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Operating temperature:-25…70 °C
Altitude:2000 m
Air humidity protection:for all climates
Storage/transport temperature:-35…70 °C
  • HNB250U
    HNB250U MCCB X250 3P 40kA 250A TM
    Similar image
    (Picture shows HNB160U)
  • HNB250U
    HNB250U MCCB X250 3P 40kA 250A TM
    HNB250U
  • HNB250U MCCB X250 3P 40kA 250A TM
  • HNB250U MCCB X250 3P 40kA 250A TM
Visitors who viewed this product also viewed the following products
HNB200U MCCB X250 3P 40kA 200A TM
MCCB X250 3P 40kA 200A TM
HNC250H MCCB h250 3P 50kA 250A LSI
MCCB h250 3P 50kA 250A LSI
HHA160U MCCB h3 x160 TM 3x160A 25kA
MCCB h3 x160 TM 3x160A 25kA
HNA160U MCCB h3 x160 TM 3x160A 40kA
MCCB h3 x160 TM 3x160A 40kA
HNB160U MCCB X250 3P 40kA 160A TM
MCCB X250 3P 40kA 160A TM
MCCB X250 4P 40kA 250A TM
*All data is subject to errors and technical modifications. All prices are recommended retail prices.