HNB251U

No picture available

MCCB X250 4P 40kA 250A TM

Cat. Ref.:HNB251U
pc.
EAN No.:

3250613347727

Pack Qty.:1 pc.
ex. GST*:3,068.36 $ / pc.
inc. GST*:3,375.20 $ / pc.
Price Group:15225
Technical Characteristics
Type of order:Toggle
Type of case:Fixed built-in
Number of poles:4 P
Type of pole:4P4D N:0;100%
Complete device with protection unit:yes
Trip Unit:TM A/A
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Motor drive integrated:no
Frequency:50/60 Hz
Rated operational voltage Ue:220/415 V
Rated insulation voltage:800 V
Rated impulse withstand voltage:8000 V
With under voltage release:no
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:40 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Breaking capacity on 1 pole with 230 V NF 60947-2:51 kA
Breaking capacity on 1 pole with 400 V NF 60947-2:9 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:40 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:4 kA
Thermal protection nob setting xIN:0,63/0,8/1
Thermal setting current on neutral pole:1 In
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Power loss per pole at In:16 W
Power loss per pole at 0.63*In:6,6 W
Power loss per pole at 0.8*In:10,2 W
Total power loss under IN:48 W
Total power loss at 0.63*In:19,7 W
Total power loss at 0.8*In:30,7 W
Tripmode:TM
Time of response when opening:10 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:12Nm
DIN rail mounting with optional adaptator:yes
Connection cross-sect. rigid cable:35 / 185mm²
Connection cross-sect. flexible conductor:35 / 150mm²
Connection:Front connection
Type of connection:Terminal
Magnetic protection nob setting xIN:5/7/9/11
Setting type In or Ith:IN
Range of the magnetic adjustment:1250/1750/2250/2750 A
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Altitude:2000 m
Storage temperature:-35 to 70 °C
Air humidity protection:for all climates
  • HNB251U
    No picture available
Visitors who viewed this product also viewed the following products
HXA001H Shunt trip 24V DC (x160-P160-x250-P250)
Shunt trip 24V DC (x160-P160-x250-P250)
HXA002H Shunt trip 48V DC (x160-P160-x250-P250)
Shunt trip 48V DC (x160-P160-x250-P250)
HNB250U MCCB X250 3P 40kA 250A TM
MCCB X250 3P 40kA 250A TM
HXA003H SHT 100-120V AC (x160-P160-x250-P250)
SHT 100-120V AC (x160-P160-x250-P250)
HXA005H SHT 380-450V AC (x160-P160-x250-P250)
SHT 380-450V AC (x160-P160-x250-P250)
HXA004H SHT 200-240V AC (x160-P160-x250-P250)
SHT 200-240V AC (x160-P160-x250-P250)
MCCB X250 4P 40kA 200A TM
HXA013H UVR 100-120V AC (x160-P160-x250-P250)
UVR 100-120V AC (x160-P160-x250-P250)
HXA014H UVR 200-240V AC (x160-P160-x250-P250)
UVR 200-240V AC (x160-P160-x250-P250)
HXA021H AX contact 1NO+NC 250VAC (x/P160-x/P250)
AX contact 1NO+NC 250VAC (x/P160-x/P250)
HNB200U MCCB X250 3P 40kA 200A TM
MCCB X250 3P 40kA 200A TM
HXA015H UVR 380-450V AC (x160-P160-x250-P250)
UVR 380-450V AC (x160-P160-x250-P250)
HXA024H AL contact 1NO+NC 250VAC (x/P160-x/P250)
AL contact 1NO+NC 250VAC (x/P160-x/P250)
*All data is subject to errors and technical modifications. All prices are recommended retail prices.