NT132C

NT132C MCB 1P 10kA C-32A 1M

Similar image
(Picture shows NT110C)

MCB 1P 10kA C-32A 1M

Cat. Ref.:NT132C
pc.
EAN No.:

3250614807053

Pack Qty.:12 pc.
ex. GST*:22.39 $ / pc.
inc. GST*:24.63 $ / pc.
Price Group:14110
Technical Characteristics
Number of protected poles:1
Number of poles:1 P
Type of pole:1 P
Fixing mode:DIN rail type O (symmetrical)
Curve:C
Bottom connection alignement for modular devices:Aligned terminal
Top connection alignement for modular devices:Aligned terminal
Frequency:50/60 Hz
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Type of supply voltage:AC
Rated operational voltage Ue:240/415 V
Rated insulation voltage:500 V
Rated impulse withstand voltage:4000 V
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Magnetic regulating currrent at 40° C:5/10 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
Rating current -15°C:37,5 A
Rating current -20°C:38,1 A
Rating current 0°C:35,8 A
Rating current 10°C:34,6 A
Rating current -10°C:37 A
Rating current 15°C:33,9 A
Rating current 20°C:33,3 A
Rating current 25°C:32,7 A
Rating current -25°C:38,7 A
Rating current 30°C:32 A
Rating current 35°C:31,3 A
Rating current 40°C:30,6 A
Rating current 45°C:29,9 A
Rating current 5°C:35,2 A
Rating current -5°C:36,4 A
Rating current 50°C:29,2 A
Rating current 55°C:28,5 A
Rating current 60°C:27,7 A
Rating current 65°C:27 A
Rating current 70°C:26,3 A
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Power loss per pole at In:4,4 W
Total power loss under IN:4,4 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:17,5 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of bottom rail clip for modular devices:metallic isolated
Type of top rail clip for modular devices:NA
Type of Bottom Connection for modular devices:BIconnect
Bottom removability for modular devices:no
Top removability for modular devices:no
Type of connection:with screw
Connection cross section of access and exit with screws, for flexible conductor:1/25 mm²
Connection cross-section of input and output with screws, for massive conductors:1/35 mm²
Standard text:IEC 60898-1, AS/NZS 60898-1
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Operating temperature:-25 … 70 °C
Class of energy limitation I²t:3
Altitude:2000 m
Air humidity protection:for all climates
Storage/transport temperature:-25 … 80 °C
  • NT132C
    NT132C MCB 1P 10kA C-32A 1M
    Similar image
    (Picture shows NT110C)
  • NT132C MCB 1P 10kA C-32A 1M
Visitors who viewed this product also viewed the following products
VE106H Vector, 6M,  outdoor,  knockouts EGY
Vector, 6M, outdoor, knockouts EGY
VE112H Encl., vector,  IP65, 12M EGY
Encl., vector, IP65, 12M EGY
*All data is subject to errors and technical modifications. All prices are recommended retail prices.