NT306C

NT306C MCB 3P 10kA C-6A 3M

Similar image
(Picture shows NT304C)

MCB 3P 10kA C-6A 3M

Cat. Ref.:NT306C
pc.
EAN No.:

3250614807183

Pack Qty.:4 pc.
ex. GST*:93.84 $ / pc.
inc. GST*:103.22 $ / pc.
Price Group:14130
Technical Characteristics
Number of protected poles:3
Number of poles:3 P
Type of pole:3 P
Fixing mode:DIN rail type O (symmetrical)
Curve:C
Bottom connection alignement for modular devices:Aligned terminal
Top connection alignement for modular devices:Aligned terminal
Frequency:50/60 Hz
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Type of supply voltage:AC
Rated operational voltage Ue:415 V
Rated insulation voltage:500 V
Rated impulse withstand voltage:4000 V
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Magnetic regulating currrent at 40° C:5/10 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
Rating current -15°C:7,5 A
Rating current -20°C:7,6 A
Rating current 0°C:7 A
Rating current 10°C:6,7 A
Rating current -10°C:7,3 A
Rating current 15°C:6,5 A
Rating current 20°C:6,4 A
Rating current 25°C:6,2 A
Rating current -25°C:7,8 A
Rating current 30°C:6 A
Rating current 35°C:5,8 A
Rating current 40°C:5,6 A
Rating current 45°C:5,4 A
Rating current 5°C:6,9 A
Rating current -5°C:7,2 A
Rating current 50°C:5,2 A
Rating current 55°C:5 A
Rating current 60°C:4,8 A
Rating current 65°C:4,6 A
Rating current 70°C:4,4 A
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Power loss per pole at In:1,34 W
Total power loss under IN:3,9 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:52,5 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of bottom rail clip for modular devices:metallic isolated
Type of top rail clip for modular devices:NA
Type of Bottom Connection for modular devices:BIconnect
Bottom removability for modular devices:no
Top removability for modular devices:no
Type of connection:with screw
Connection cross section of access and exit with screws, for flexible conductor:1/25 mm²
Connection cross-section of input and output with screws, for massive conductors:1/35 mm²
Can be accessorized:yes
Standard text:IEC 60898-1, AS/NZS 60898-1
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Class of energy limitation I²t:3
Altitude:2000 m
Storage temperature:-25 to 80 °C
Air humidity protection:for all climates
  • NT306C
    NT306C MCB 3P 10kA C-6A 3M
    Similar image
    (Picture shows NT304C)
  • NT306C MCB 3P 10kA C-6A 3M
Visitors who viewed this product also viewed the following products
NT304C MCB 3P 10kA C-4A 3M
MCB 3P 10kA C-4A 3M
NT302C MCB 3P 10kA C-2A 3M
MCB 3P 10kA C-2A 3M
NT310C MCB 3P 10kA C-10A 3M
MCB 3P 10kA C-10A 3M
NT316C MCB 3P 10kA C-16A 3M
MCB 3P 10kA C-16A 3M
NT263C MCB 2P 10kA C-63A 2M
MCB 2P 10kA C-63A 2M
NT240C MCB 2P 10kA C-40A 2M
MCB 2P 10kA C-40A 2M
NT250C MCB 2P 10kA C-50A 2M
MCB 2P 10kA C-50A 2M
NT320C MCB 3P 10kA C-20A 3M
MCB 3P 10kA C-20A 3M