NDN206A

NDN206A MCB 2P 10kA D-6A 2M

NDN206A
NDN206A MCB 2P 10kA D-6A 2M
NDN206A MCB 2P 10kA D-6A 2M

MCB 2P 10kA D-6A 2M

Cat. Ref.:NDN206A
pc.
EAN No.:

3250614619069

Pack Qty.:6 pc.
ex. GST*:202.05 $ / pc.
inc. GST*:222.26 $ / pc.
Price Group:14220
Technical Characteristics
Neutral position:without neutral
Number of protected poles:2
Number of poles:2 P
Type of pole:2 P
Curve:D
Concurrently switching N-neutral:no
Top connection alignement for modular devices:Aligned terminal
Bottom connection alignement for modular devices:Aligned terminal
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Rated operational voltage Ue:415 V
Type of supply voltage:AC
Rated insulation voltage:500 V
Max operating voltage:440 V
Rated impulse withstand voltage:6000 V
Minimum threshold voltage (Ue min):12 V
Rated current:6 A
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:10 / 14,4 In
min/maxi threshold value of the DC magnetic operation:15 / 30 In
min/maxi threshold value of the DC thermal operation:1,13 / 1,45 In
Rating current -10°C according to IEC 60947:8 A
Rating current -15°C according to IEC 60947:8,15 A
Rating current -20°C according to IEC 60947:8,29 A
Rating current -25°C according to IEC 60947:8,43 A
Rating current -5°C according to IEC 60947:7,86 A
Rating current 0°C according to IEC 60947:7,71 A
Rating current 10°C according to IEC 60947:7,4 A
Rating current 150°C according to IEC 60947:7,24 A
Rating current 20°C according to IEC 60947:7,07 A
Rating current 25°C according to IEC 60947:6,91 A
Rating current 30°C according to IEC 60947:6,73 A
Rating current 35°C according to IEC 60947:6,56 A
Rating current 40°C according to IEC 60947:6,38 A
Rating current 45°C according to IEC 60947:6,19 A
Rating current 5°C according to IEC 60947:7,55 A
Rating current 50°C according to IEC 60947:6 A
Rating current 55°C according to IEC 60947:5,8 A
Rating current 60°C according to IEC 60947:5,6 A
Rating current 65°C according to IEC 60947:5,38 A
Rating current 70°C according to IEC 60947:5,16 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:7,5 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:10 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 380V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:15 kA
Rating current -25°C:7,51 A
Rating current -20°C:7,39 A
Rating current -15°C:7,26 A
Rating current -10°C:7,13 A
Rating current -5°C:7 A
Rating current 0°C:6,87 A
Rating current 5°C:6,73 A
Rating current 10°C:6,59 A
Rating current 25°C:6,15 A
Rating current 30°C:6 A
Rating current 35°C:5,84 A
Rating current 40°C:5,68 A
Rating current 45°C:5,52 A
Rating current 50°C:5,35 A
Rating current 55°C:5,17 A
Rating current 60°C:4,99 A
Rating current 65°C:4,8 A
Rating current 70°C:4,6 A
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Frequency:50 to 60 Hz
Maximum power loss per pole according to the product standard:3 W
Total power loss under IN:2,68 W
Power loss per pole at In:1,34 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:35 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:BIconnect
Top removability for modular devices:yes
Bottom removability for modular devices:yes
Suitable for flush-mounting:yes
Connection cross-section at output with screw, for flexible conductor:1 / 25 mm²
Connection cross-section at output with screw, for massive conductor:1 / 35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 35 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 25 mm²
Downstream cage clamp delivery status:opened
Upstream cage clamp delivery status:opened
Can be accessorized:yes
Standard text:EN 60898-1, AS/NZS 60898-1
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP20
Operating temperature:-25…70 °C
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
Storage/transport temperature:-25…80 °C
Temperature of calibration:30 °C
  • NDN206A
    NDN206A MCB 2P 10kA D-6A 2M
    NDN206A
  • NDN206A
    NDN206A MCB 2P 10kA D-6A 2M
    NDN206A
  • NDN206A MCB 2P 10kA D-6A 2M
  • NDN206A MCB 2P 10kA D-6A 2M
Visitors who viewed this product also viewed the following products
NDN106A MCB 1P 10kA/15kA D-6A 1M
MCB 1P 10kA/15kA D-6A 1M
NDN163A MCB 1P 10kA/15kA D-63A 1M
MCB 1P 10kA/15kA D-63A 1M
NDN210A MCB 2P 10kA/15kA D-10A 2M
MCB 2P 10kA/15kA D-10A 2M
NDN216A MCB 2P 10kA/15kA D-16A 2M
MCB 2P 10kA/15kA D-16A 2M
NDN220A MCB 2P 10kA/15kA D-20A 2M
MCB 2P 10kA/15kA D-20A 2M
NDN225A MCB 2P 10kA/15kA D-25A 2M
MCB 2P 10kA/15kA D-25A 2M
HMD199T MCB 1P 15kA D-125A 1.5M
MCB 1P 15kA D-125A 1.5M
HMD280T MCB 2P 15kA D-80A 3M
MCB 2P 15kA D-80A 3M
MDN350P MCB 3P 6kA D-50A 3M
MCB 3P 6kA D-50A 3M
MDN363P MCB 3P 6kA D-63A 3M
MCB 3P 6kA D-63A 3M
MDN363R MCB 3P 6kA D-63A 3M
MCB 3P 6kA D-63A 3M
NDN110A MCB 1P 10kA/15kA D-10A 1M
MCB 1P 10kA/15kA D-10A 1M
NDN116A MCB 1P 10kA/15kA D-16A 1M
MCB 1P 10kA/15kA D-16A 1M
NDN120A MCB 1P 10kA/15kA D-20A 1M
MCB 1P 10kA/15kA D-20A 1M
NDN125A MCB 1P 10kA/15kA D-25A 1M
MCB 1P 10kA/15kA D-25A 1M
*All data is subject to errors and technical modifications. All prices are recommended retail prices.