NDN216A MCB 2P 10kA/15kA D-16A 2M

NDN216A

MCB 2P 10kA/15kA D-16A 2M

Cat. Ref.:NDN216A
pc.
EAN No.:

3250614619090

Pack Qty.:6 pc.
ex. GST*:194.22 $ / pc.
inc. GST*:213.64 $ / pc.
Price Group:14220
Technical Characteristics
Neutral position:without neutral
Number of protected poles:2
Number of poles:2 P
Type of pole:2 P
Fixing mode:Din-Rail
Curve:D
Compatible with DIN rail mounting:yes
With fault indicator:no
Bottom connection alignement for modular devices:Aligned terminal
Top connection alignement for modular devices:Aligned terminal
Type of supply voltage:AC
Rated operational voltage Ue:400 V
Minimum threshold voltage (Ue min):12 V
Rated insulation voltage:500 V
Rated impulse withstand voltage:6000 V
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 380V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Magnetic regulating currrent at 40° C:10/14,4 In
min/maxi threshold value of the DC magnetic operation:15/30 In
min/maxi threshold value of the AC thermal operation:1,13/1,45 In
min/maxi threshold value of the DC thermal operation:1,13/1,45 In
Rating current -15°C:19,75 A
Rating current -20°C:20,12 A
Rating current 0°C:18,58 A
Rating current 10°C:17,76 A
Rating current -10°C:19,37 A
Rating current 25°C:16,46 A
Rating current -25°C:20,49 A
Rating current 30°C:16 A
Rating current 35°C:15,53 A
Rating current 40°C:15,04 A
Rating current 45°C:14,54 A
Rating current 5°C:18,18 A
Rating current -5°C:18,98 A
Rating current 50°C:14,02 A
Rating current 55°C:13,48 A
Rating current 60°C:12,91 A
Rating current 65°C:12,32 A
Rating current 70°C:11,7 A
Rating current 0°C according to IEC 60947-2:21,21 A
Rating current 10°C according to IEC 60947-2:20,28 A
Rating current -10°C according to IEC 60947-2:22,11 A
Rating current 150°C according to IEC 60947-2:19,79 A
Rating current -15°C according to IEC 60947-2:22,54 A
Rating current 20°C according to IEC 60947-2:19,3 A
Rating current -20°C according to IEC 60947-2:22,97 A
Rating current 25°C according to IEC 60947-2:18,79 A
Rating current -25°C according to IEC 60947-2:23,39 A
Rating current 30°C according to IEC 60947-2:18,26 A
Rating current 35°C according to IEC 60947-2:17,73 A
Rating current 40°C according to IEC 60947-2:17,17 A
Rating current 45°C according to IEC 60947-2:16,59 A
Rating current 5°C according to IEC 60947-2:20,75 A
Rating current -5°C according to IEC 60947-2:21,66 A
Rating current 50°C according to IEC 60947-2:16 A
Rating current 55°C according to IEC 60947-2:15,38 A
Rating current 60°C according to IEC 60947-2:14,74 A
Rating current 65°C according to IEC 60947-2:14,06 A
Rating current 70°C according to IEC 60947-2:13,36 A
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Power loss per pole at In:2,7 W
Maximum power loss per pole according to the product standard:3,5 W
Total power loss under IN:5,34 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:35 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of bottom rail clip for modular devices:plastic
Type of top rail clip for modular devices:NA
Type of Bottom Connection for modular devices:BIconnect
Bottom removability for modular devices:yes
Top removability for modular devices:yes
Suitable for flush-mounting:yes
Upstream cage clamp delivery status:opened
Downstream cage clamp delivery status:opened
Connection cross-section at output with screw, for flexible conductor:1/25 mm²
Connection cross-section of the access with screws, with flexible conductor:1/25 mm²
Connection cross-section at output with screw, for massive conductor:1/35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1/35 mm²
Can be accessorized:yes
Standard text:EN 60898-1, IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
Storage temperature:-25 to 80 °C
Temperature of calibration:50 °C
  • NDN216A
    NDN216A MCB 2P 10kA/15kA D-16A 2M
    NDN216A
  • NDN216A MCB 2P 10kA/15kA D-16A 2M
Visitors who viewed this product also viewed the following products
NDN210A MCB 2P 10kA D-10A 2M
MCB 2P 10kA D-10A 2M
NDN225A MCB 2P 10kA/15kA D-25A 2M
MCB 2P 10kA/15kA D-25A 2M
NDN220A MCB 2P 10kA/15kA D-20A 2M
MCB 2P 10kA/15kA D-20A 2M
NDN206A MCB 2P 10kA D-6A 2M
MCB 2P 10kA D-6A 2M
NDN232A MCB 2P 10kA/15kA D-32A 2M
MCB 2P 10kA/15kA D-32A 2M
*All data is subject to errors and technical modifications. All prices are recommended retail prices.