  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

NDN332A

NDN332A MCB 3P 10kA/15kA D-32A 3M

NDN332A

MCB 3P 10kA/15kA D-32A 3M

Cat. Ref.:NDN332A
pc.
EAN No.:

3250614619274

Pack Qty.:4 pc.
ex. GST*:235.74 $ / pc.
inc. GST*:259.31 $ / pc.
Price Group:14230
Technical Characteristics
Neutral position:without neutral
Number of protected poles:3
Number of poles:3 P
Type of pole:3 P
Fixing mode:Din-Rail
Curve:D
Concurrently switching N-neutral:no
Compatible with DIN rail mounting:yes
With fault indicator:no
Top connection alignement for modular devices:Aligned terminal
Bottom connection alignement for modular devices:Aligned terminal
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Rated operational voltage Ue:400 V
Type of supply voltage:AC
Rated insulation voltage:500 V
Rated impulse withstand voltage:6000 V
Minimum threshold voltage (Ue min):12 V
Rated current:32 A
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:10 / 14,4 In
min/maxi threshold value of the DC magnetic operation:15 / 30 In
min/maxi threshold value of the DC thermal operation:1,13 / 1,45 In
Rating current -10°C according to IEC 60947:41,08 A
Rating current -15°C according to IEC 60947:41,74 A
Rating current -20°C according to IEC 60947:42,4 A
Rating current -25°C according to IEC 60947:43,05 A
Rating current -5°C according to IEC 60947:40,4 A
Rating current 0°C according to IEC 60947:39,71 A
Rating current 10°C according to IEC 60947:38,29 A
Rating current 150°C according to IEC 60947:37,56 A
Rating current 20°C according to IEC 60947:36,82 A
Rating current 25°C according to IEC 60947:36,06 A
Rating current 30°C according to IEC 60947:35,29 A
Rating current 35°C according to IEC 60947:34,49 A
Rating current 40°C according to IEC 60947:33,68 A
Rating current 45°C according to IEC 60947:32,85 A
Rating current 5°C according to IEC 60947:39,01 A
Rating current 50°C according to IEC 60947:32 A
Rating current 55°C according to IEC 60947:31,09 A
Rating current 60°C according to IEC 60947:30,16 A
Rating current 65°C according to IEC 60947:29,19 A
Rating current 70°C according to IEC 60947:28,19 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:7,5 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:10 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 380V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:15 kA
Rating current -25°C:39,04 A
Rating current -20°C:38,45 A
Rating current -15°C:37,86 A
Rating current -10°C:37,25 A
Rating current -5°C:36,64 A
Rating current 0°C:36,01 A
Rating current 5°C:35,37 A
Rating current 10°C:34,73 A
Rating current 25°C:32,7 A
Rating current 30°C:32 A
Rating current 35°C:31,26 A
Rating current 40°C:30,5 A
Rating current 45°C:29,72 A
Rating current 50°C:28,92 A
Rating current 55°C:28,1 A
Rating current 60°C:27,26 A
Rating current 65°C:26,38 A
Rating current 70°C:25,48 A
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Frequency:50 to 60 Hz
Maximum power loss per pole according to the product standard:6 W
Total power loss under IN:12,3 W
Power loss per pole at In:4,22 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:52,5 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:BIconnect
Top removability for modular devices:yes
Bottom removability for modular devices:yes
Suitable for flush-mounting:yes
360° product mounting position:yes
Connection cross-section at output with screw, for flexible conductor:1 / 25 mm²
Connection cross-section at output with screw, for massive conductor:1 / 35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 35 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 25 mm²
Downstream cage clamp delivery status:opened
Upstream cage clamp delivery status:opened
Can be accessorized:yes
With transparent product label holder:yes
Standard text:EN 60898-1, IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
Temperature of calibration:50 °C
  • NDN332A
    NDN332A MCB 3P 10kA/15kA D-32A 3M
    NDN332A
  • NDN332A MCB 3P 10kA/15kA D-32A 3M
Visitors who viewed this product also viewed the following products
NDN320A MCB 3P 10kA/15kA D-20A 3M
MCB 3P 10kA/15kA D-20A 3M
HA406 Load break switch visib.breaking 4P 125A
Load break switch visib.breaking 4P 125A
HMD199T MCB 1P 15kA D-125A 1.5M
MCB 1P 15kA D-125A 1.5M
MDN110P MCB 1P 6kA D-10A 1M
MCB 1P 6kA D-10A 1M
MDN320P MCB 3P 6kA D-20A 3M
MCB 3P 6kA D-20A 3M
MDN350P MCB 3P 6kA D-50A 3M
MCB 3P 6kA D-50A 3M
MDN363P MCB 3P 6kA D-63A 3M
MCB 3P 6kA D-63A 3M
MDN363R MCB 3P 6kA D-63A 3M
MCB 3P 6kA D-63A 3M
NDN106A MCB 1P 10kA/15kA D-6A 1M
MCB 1P 10kA/15kA D-6A 1M
NDN110A MCB 1P 10kA/15kA D-10A 1M
MCB 1P 10kA/15kA D-10A 1M
NDN116A MCB 1P 10kA/15kA D-16A 1M
MCB 1P 10kA/15kA D-16A 1M
NDN120A MCB 1P 10kA/15kA D-20A 1M
MCB 1P 10kA/15kA D-20A 1M
NDN125A MCB 1P 10kA/15kA D-25A 1M
MCB 1P 10kA/15kA D-25A 1M
NDN132A MCB 1P 10kA/15kA D-32A 1M
MCB 1P 10kA/15kA D-32A 1M
NDN140A MCB 1P 10kA/15kA D-40A 1M
MCB 1P 10kA/15kA D-40A 1M
*All data is subject to errors and technical modifications. All prices are recommended retail prices.