  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

NDN425A

NDN425A MCB 4P 10kA/15kA D-25A 4M

Similar image
(Picture shows NDN440A)
NDN425A MCB 4P 10kA/15kA D-25A 4M
NDN425A MCB 4P 10kA/15kA D-25A 4M

MCB 4P 10kA/15kA D-25A 4M

Cat. Ref.:NDN425A
pc.
EAN No.:

3250614619410

Pack Qty.:3 pc.
ex. GST*:269.44 $ / pc.
inc. GST*:296.38 $ / pc.
Price Group:14240
Technical Characteristics
Neutral position:without neutral
Number of protected poles:4
Number of poles:4 P
Type of pole:4 P
Fixing mode:Din-Rail
Curve:D
Concurrently switching N-neutral:no
Compatible with DIN rail mounting:yes
With fault indicator:no
Top connection alignement for modular devices:Aligned terminal
Bottom connection alignement for modular devices:Aligned terminal
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Rated operational voltage Ue:400 V
Type of supply voltage:AC
Rated insulation voltage:500 V
Rated impulse withstand voltage:6000 V
Minimum threshold voltage (Ue min):12 V
Rated current:25 A
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:10 / 14,4 In
min/maxi threshold value of the DC magnetic operation:15 / 30 In
min/maxi threshold value of the DC thermal operation:1,13 / 1,45 In
Rating current -10°C according to IEC 60947:35,44 A
Rating current -15°C according to IEC 60947:35,87 A
Rating current -20°C according to IEC 60947:36,3 A
Rating current -25°C according to IEC 60947:36,73 A
Rating current -5°C according to IEC 60947:35,01 A
Rating current 0°C according to IEC 60947:34,58 A
Rating current 10°C according to IEC 60947:33,72 A
Rating current 150°C according to IEC 60947:33,29 A
Rating current 20°C according to IEC 60947:32,86 A
Rating current 25°C according to IEC 60947:32,43 A
Rating current 30°C according to IEC 60947:32 A
Rating current 35°C according to IEC 60947:30,25 A
Rating current 40°C according to IEC 60947:28,5 A
Rating current 45°C according to IEC 60947:26,75 A
Rating current 5°C according to IEC 60947:34,15 A
Rating current 50°C according to IEC 60947:25 A
Rating current 55°C according to IEC 60947:23,25 A
Rating current 60°C according to IEC 60947:21,5 A
Rating current 65°C according to IEC 60947:19,75 A
Rating current 70°C according to IEC 60947:18 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:7,5 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:10 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 380V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:15 kA
Rating current -25°C:32,08 A
Rating current -20°C:31,44 A
Rating current -15°C:30,79 A
Rating current -10°C:30,15 A
Rating current -5°C:29,51 A
Rating current 0°C:28,86 A
Rating current 5°C:28,22 A
Rating current 10°C:27,58 A
Rating current 25°C:25,64 A
Rating current 30°C:25 A
Rating current 35°C:24,36 A
Rating current 40°C:23,71 A
Rating current 45°C:23,07 A
Rating current 50°C:22,43 A
Rating current 55°C:21,78 A
Rating current 60°C:21,14 A
Rating current 65°C:20,49 A
Rating current 70°C:19,85 A
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Frequency:50 to 60 Hz
Maximum power loss per pole according to the product standard:4,5 W
Total power loss under IN:14,75 W
Power loss per pole at In:3,75 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:70 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:BIconnect
Top removability for modular devices:yes
Bottom removability for modular devices:yes
Suitable for flush-mounting:yes
360° product mounting position:yes
Connection cross-section at output with screw, for flexible conductor:1 / 25 mm²
Connection cross-section at output with screw, for massive conductor:1 / 35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 35 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 25 mm²
Downstream cage clamp delivery status:opened
Upstream cage clamp delivery status:opened
Can be accessorized:yes
With transparent product label holder:yes
Standard text:EN 60898-1, IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
Temperature of calibration:50 °C
  • NDN425A
    NDN425A MCB 4P 10kA/15kA D-25A 4M
    Similar image
    (Picture shows NDN440A)
  • NDN425A
    NDN425A MCB 4P 10kA/15kA D-25A 4M
    NDN425A
  • NDN425A MCB 4P 10kA/15kA D-25A 4M
  • NDN425A MCB 4P 10kA/15kA D-25A 4M
Visitors who viewed this product also viewed the following products
NDN432A MCB 4P 10kA/15kA D-32A 4M
MCB 4P 10kA/15kA D-32A 4M
NDN440A MCB 4P 10kA/15kA D-40A 4M
MCB 4P 10kA/15kA D-40A 4M
HMD380T MCB 3P 15kA D-80A 4.5M
MCB 3P 15kA D-80A 4.5M
MDN163P MCB 1P 6kA D-63A 1M
MCB 1P 6kA D-63A 1M
NDN420A MCB 4P 10kA/15kA D-20A 4M
MCB 4P 10kA/15kA D-20A 4M
*All data is subject to errors and technical modifications. All prices are recommended retail prices.