RCBO 1M 1P+N 6kA D-20A 30mA A ADD920T

EAN
3250611033431
Packaging
1 Piece

Technical properties

Architecture
  • Neutral position
    right
  • Number of protected poles
    1
  • Number of poles
    2 P
  • Type of pole
    1P+N
  • Fixing mode
    DIN rail type O (symmetrical)
  • Curve
    D
Configuration
  • Number of modules
    1
Connectivity
  • Top connection alignement for modular devices
    Shifted terminal
  • Bottom connection alignement for modular devices
    Aligned terminal
Main electrical features
  • Rated short circuit breaking capacity Icn AC according IEC60898-1
    6 kA
  • Rated operational voltage Ue
    230 / 240 V
  • Type of supply voltage
    AC
  • Frequency
    50 Hz
Voltage
  • Rated insulation voltage
    440 V
  • Max operating voltage
    264 V
  • Rated impulse withstand voltage
    4 kV
Electric current
  • Rated residual operating current
    30 mA
  • Rated current
    20 A
  • Withstand not tripping on 8-20 μs wave
    0.25 kA
  • Breaking and opening capacity
    4.5 kA
  • min/maxi threshold value of the AC thermal operation
    1.13 / 1.45 In
  • Magnetic regulating currrent
    10 / 15 In
Electric current / temperature
  • Rating current -25°C
    25.5 A
  • Rating current -20°C
    25 A
  • Rating current -15°C
    24.5 A
  • Rating current -10°C
    24 A
  • Rating current -5°C
    23.5 A
  • Rating current 0°C
    23 A
  • Rating current 5°C
    22.5 A
  • Rating current 10°C
    22 A
  • Rating current 15°C
    21.5 A
  • Rating current 20°C
    21 A
  • Rating current 25°C
    20.5 A
  • Rating current 30°C
    20 A
  • Rating current 35°C
    19.6 A
  • Rating current 40°C
    19.2 A
  • Rating current 45°C
    18.8 A
  • Rating current 50°C
    18.4 A
  • Rating current 55°C
    18 A
  • Rating current 60°C
    17.6 A
  • Rating current 65°C
    17.2 A
  • Rating current 70°C
    16.8 A
Dimensions
  • Depth of installed product
    70 mm
  • Height of installed product
    85 mm
  • Width of installed product
    17.7 mm
Frequency
  • Frequency
    50 Hz
Power
  • Total power loss under IN
    11.68 W
  • Power loss per pole at In
    7.58 W
Installation, mounting
  • Type of top connection for modular devices
    with screw
  • Type of bottom rail clip for modular devices
    plastic
  • Type of Bottom Connection for modular devices
    BIconnect
  • Top removability for modular devices
    No
  • Bottom removability for modular devices
    Yes
  • Suitable for flush-mounting
    Yes
Connection
  • Connection cross-section at output with screw, for flexible conductor
    1 / 10 mm²
  • Connection cross-section at output with screw, for massive conductor
    1 / 16 mm²
  • Connection cross-section for rigid conductor, upstream terminals with screws
    1 / 16 mm²
  • Connection cross-section of the access with screws, with flexible conductor
    1 / 10 mm²
  • Downstream cage clamp delivery status
    opened
  • Upstream cage clamp delivery status
    opened
  • Connection cross-section of input and output with screws, for massive conductors
    1 / 16 mm²
  • Connection cross section of access and exit with screws, for flexible conductor
    1 / 10 mm²
Cable
  • Length of conductors used for the heating test (m) according to product standard
    1 m
  • Conductor cross-section used for heating test(mm²) according to product standard
    2.5 mm²
Equipment
  • Type selective
    No
  • Can be accessorized
    No
  • With transparent product label holder
    Yes
Standards
  • Standard text
    IEC 61009-1, AS/NZS 61009-1
  • European directive WEEE
    concerned
Safety
  • Protection index IP
    IP20
  • Residual current type
    A
Use conditions
  • Operating temperature
    -25…70 °C
  • Degree of pollution according to IEC 60664 / IEC 60947-2
    2
  • Class of energy limitation I²t
    3
  • Altitude
    2000 m
  • Storage/transport temperature
    -25…80 °C
temperatur
  • Temperature of calibration
    30 °C
  • Ambient air temperature during heating test according to the product standard
    23.4 °C
  • Max. admissible temperature on accessible parts (intended to be touched)
    64.9 °C
  • Max. admissible temperature on accessible parts (manual operating means)
    48.9 °C
  • Max. admissible temperature on access. parts (not touched for normal operation)
    94.1 °C
  • Max. admissible temperature on terminals
    82.2 °C
  • Temp.-rise limits for access. parts (toggle) according to product standard
    40 K
  • Temp.-rise limits for access. parts (not touched) according to product standard
    60 K
  • Temp.rise limits for access. parts (to be touched) according to product standard
    40 K
  • Temperature-rise limits for terminals according to the product standard
    65 K
  • Temperature-rise measured on accessible parts at In (manual operating means)
    8.9 K
  • Temperature-rise measured on access. parts at In (not touched normal operation)
    54.1 K
  • Temperature-rise measured on accessible parts at In (intended to be touched)
    24.9 K
  • Temperature-rise measured on terminals at In
    42.2 K

Downloads

  • Product image

    Image ADD920T  | Hager Australia

    Product Image ADD920T

  • ProductNotice

    Image Instruction manuals for ADD920T  | Hager Australia

    Instruction manuals for ADD920T

    PDF
    1 MB
  • User brochure

    Image Onekonekt_Brochure  | Hager Australia

    Onekonekt_Brochure

    PDF
    2 MB
  • ProductECDeclaration

    Image Declaration  | Hager Australia

    Declaration

    PDF
    107 KB
  • ProductROHS

    Image RoHS certificate for ADD920T  | Hager Australia

    RoHS certificate for ADD920T

    PDF
    33 KB
    Image RoHS certificate for ADD920T  | Hager Australia

    RoHS certificate for ADD920T

    PDF
    33 KB
More documentation