CDA240T

CDA240T RCCB 2P 40A 30mA A

CDA240T

RCCB 2P 40A 30mA A

Cat. Ref.:CDA240T
pc.
EAN No.:

3250611615453

Pack Qty.:1 pc.
ex. GST*:118.10 $ / pc.
inc. GST*:129.91 $ / pc.
Price Group:16100
Technical Characteristics
Neutral position:right
Number of poles:2 P
Type of pole:2 P
Fixing mode:DIN rail type O (symmetrical)
With fault indicator:yes
Rated operational voltage Ue:230 V
Type of supply voltage:AC
Frequency:50 Hz
Rated insulation voltage:500 V
Max operating voltage:253 V
Rated impulse withstand voltage:4000 V
Rated residual operating current:30 mA
Rated current:40 A
Withstand not tripping on 8-20 μs wave:0,25 kA
Breaking and opening capacity:1,5 kA
Rated conditional short-circuit current Inc according to EN 61008-1:6 kA
Rating current -25°C:40 A
Rating current -20°C:40 A
Rating current -15°C:40 A
Rating current -10°C:40 A
Rating current -5°C:40 A
Rating current 0°C:40 A
Rating current 5°C:40 A
Rating current 10°C:40 A
Rating current 15°C:40 A
Rating current 20°C:40 A
Rating current 25°C:40 A
Rating current 30°C:40 A
Rating current 35°C:40 A
Rating current 40°C:40 A
Rating current 45°C:38 A
Rating current 50°C:37 A
Rating current 55°C:34 A
Rating current 60°C:30 A
Rating current 65°C:26 A
Rating current 70°C:21 A
Frequency:50 Hz
Total power loss under IN:6,24 W
Short-time delayed tripping:no
Electric endurance in number of cycles:2000
Number of mechanical operations:4000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:35 mm
Construction size (DIN 43880):1
Tightening torque:2,8Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:plastic
360° product mounting position:yes
Connection cross-sect. flexible conductor:16mm²
Connection cross-sect. rigid cable:25mm²
Type of connection:with screw
Type selective:no
Accept terminal cover:no
Standard text:IEC 61008-1, AS/NZS 61008-1
European directive WEEE:not concerned
Protection index IP:IP20
Residual current type:A
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
  • CDA240T
    CDA240T RCCB 2P 40A 30mA A
    CDA240T
  • CDA240T RCCB 2P 40A 30mA A
Visitors who viewed this product also viewed the following products
ADA940T RCBO 1P+N 6kA C-40A 30mA A Class
RCBO 1P+N 6kA C-40A 30mA A Class
MSN120 MCB 1P 6kA C-20A 1M
MCB 1P 6kA C-20A 1M
CDA440T RCCB 4P 40A 30mA A
RCCB 4P 40A 30mA A
BD163T Add-on-block 3P 63A 30mA A 1mod
Add-on-block 3P 63A 30mA A 1mod
ADA920T RCBO 1P+N 6kA C-20A 30mA A Class
RCBO 1P+N 6kA C-20A 30mA A Class
MSN116 MCB 1P 6kA C-16A 1M
MCB 1P 6kA C-16A 1M
MSN132 MCB 1P 6kA C-32A 1M
MCB 1P 6kA C-32A 1M
ADA910T RCBO 1P+N 6kA C-10A 30mA type A Class
RCBO 1P+N 6kA C-10A 30mA type A Class
ADC920T RCBO 1M 1P+N 6kA C-20A 30mA A
RCBO 1M 1P+N 6kA C-20A 30mA A
MSN110 MCB 1P 6kA C-10A 1M
MCB 1P 6kA C-10A 1M
ADC332T RCBO 1P 6kA C-32A 30mA A Class 1M
RCBO 1P 6kA C-32A 30mA A Class 1M
ADA140T RCBO 1P 6kA C-40A 30mA A
RCBO 1P 6kA C-40A 30mA A
ADA932T RCBO 1P+N 6kA C-32A 30mA A Class
RCBO 1P+N 6kA C-32A 30mA A Class
ADM440T RCBO 4P 6kA C-40A 30mA A
RCBO 4P 6kA C-40A 30mA A
*All data is subject to errors and technical modifications. All prices are recommended retail prices.