  • e-Catalogue
  • Downloads,
    Services & Support
  • News, Exhibitions
    & Case Studies
  • AS/NZS 3000:2018
    Wiring Rules
  • About Us

HEE801H

HEE801H MCCB h1000 4P 70kA 800A LSI

HEE801H

MCCB h1000 4P 70kA 800A LSI

Cat. Ref.:HEE801H
pc.
EAN No.:

3250613349790

Pack Qty.:1 pc.
ex. GST*:5,689.10 $ / pc.
inc. GST*:6,258.01 $ / pc.
Price Group:15705
Technical Characteristics
Type of order:Toggle
Number of poles:4 P
Type of pole:4P4D N:0/50/100%
Complete device with protection unit:yes
Trip Unit:LSI
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Rated operational voltage Ue:220 / 690 V
Frequency:50/60 Hz
Rated insulation voltage:800 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:800 A
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:20 kA
Thermal protection nob setting xIN:0,4 / 0,5 / 0,63 / 0,9 / 0,95 / 1
Thermal setting current on neutral pole:0 / 0,5 / 1 In
Breaking capacity on 1 pole for IT 230V NF 60947-2:60 kA
Breaking capacity on 1 pole for IT 400V NF 60947-2:9 kA
Rated service breaking capacity Ics AC according IEC 60947-2:71 %
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:100 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:100 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:70 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:70 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:65 kA
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Total power loss under IN:153,6 W
Power loss per pole at In:51,2 W
Tripmode:LSI
Thermal protection trip time:5 / 10 / 11 / 19 / 21 / 29 ms
Time of response when opening:10 ms
Magnetic trip delay time:100 to 200 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:65Nm
DIN rail mounting with optional adaptator:no
Connection cross-sect. flexible conductor:2x240mm²
Connection cross-sect. rigid cable:2x240mm²
Connection:Front connection
Type of connection:Terminal
Range of the magnetic adjustment:4480 / 5600 / 7000 / 8960 / 9600 / 9600 / 9600 A
Magnetic protection nob setting xIN:2,5 / 5 / 10
Setting type In or Ith:IrTh
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Operating temperature:-25…70 °C
Altitude:2000 m
Air humidity protection:for all climates
Storage/transport temperature:-35…70 °C
  • HEE801H
    HEE801H MCCB h1000 4P 70kA 800A LSI
    HEE801H
  • HEE801H MCCB h1000 4P 70kA 800A LSI
Visitors who viewed this product also viewed the following products
ADA913T RCBO 1P+N 6kA C-13A 30mA A Class
RCBO 1P+N 6kA C-13A 30mA A Class
ADA932T RCBO 1P+N 6kA C-32A 30mA A Class
RCBO 1P+N 6kA C-32A 30mA A Class
ESC225S Humfree Contactor 25A,  2NO,  230V
Humfree Contactor 25A, 2NO, 230V
HA304 LOAD BREAK SWITCH 3P 80A
LOAD BREAK SWITCH 3P 80A
HA408 Load break switch visib.breaking 4P 200A
Load break switch visib.breaking 4P 200A
HA457 Load break switch 4P 400A
Load break switch 4P 400A
HEC126H MCCB h250 4P 70kA 125A LSI
MCCB h250 4P 70kA 125A LSI
HEE970H MCCB h1000 3P 70kA 1000A LSI
MCCB h1000 3P 70kA 1000A LSI
HHA030Z MCCB X160 1P 25kA 32A
MCCB X160 1P 25kA 32A
HHA064U MCCB h3 x160 TM 4x63A 25kA
MCCB h3 x160 TM 4x63A 25kA
HHA100U MCCB h3 x160 TM 3x100A 25kA
MCCB h3 x160 TM 3x100A 25kA
HHA101U MCCB h3 x160 TM 4x100A 25kA
MCCB h3 x160 TM 4x100A 25kA
HMD180T MCB 1P 15kA D-80A 1.5M
MCB 1P 15kA D-80A 1.5M
HMF399T MCB 3P 10kA C-125A 4.5M
MCB 3P 10kA C-125A 4.5M
HND400H MCCB h630 3P 50kA 400A LSI
MCCB h630 3P 50kA 400A LSI
*All data is subject to errors and technical modifications. All prices are recommended retail prices.