HND630H

HND630H MCCB h630 3P 50kA 630A LSI

HND630H

MCCB h630 3P 50kA 630A LSI

Cat. Ref.:HND630H
pc.
EAN No.:

3250613349554

Pack Qty.:1 pc.
ex. GST*:3,389.10 $ / pc.
inc. GST*:3,728.01 $ / pc.
Price Group:15525
Technical Characteristics
Type of order:Toggle
Number of poles:3 P
Type of pole:3P3D
Complete device with protection unit:yes
Trip Unit:LSI
Integrated earth fault protection:no
Compatible with DIN rail mounting:no
Rated operational voltage Ue:220 / 690 V
Frequency:50/60 Hz
Rated insulation voltage:800 V
Rated impulse withstand voltage:8 kV
With under voltage release:no
Rated current:630 A
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2:20 kA
Thermal protection nob setting xIN:0,4 / 0,5 / 0,63 / 0,8 / 0,9 / 0,95 / 1
Breaking capacity on 1 pole for IT 230V NF 60947-2:51 kA
Breaking capacity on 1 pole for IT 400V NF 60947-2:9 kA
Rated service breaking capacity Ics AC according IEC 60947-2:100 %
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:85 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:50 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:50 kA
Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2:45 kA
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:1
Correction factor of rating current for 4 and 5 devices placed side-by-side:1
Correction factor of rating current for 6 devices placed side-by-side:1
Total power loss under IN:120 W
Power loss per pole at In:40 W
Tripmode:LSI
Thermal protection trip time:5 / 10 / 11 / 16 / 21 ms
Time of response when opening:10 ms
Magnetic trip delay time:100 to 200 ms
Electric endurance in number of cycles:1000
Number of mechanical operations:4000
Tightening torque:22Nm
DIN rail mounting with optional adaptator:no
Connection cross-sect. flexible conductor:35 / 240mm²
Connection cross-sect. rigid cable:35 / 240mm²
Connection:Front connection
Type of connection:Terminal
Range of the magnetic adjustment:3500 / 4410 / 5600 / 6300 / 6300 / 6300 / 6300 / 6300 A
Magnetic protection nob setting xIN:2,5 / 5 / 8
Setting type In or Ith:IrTh
Motor drive optional:yes
Category of use:A
Standard text:IEC 60947-2
European directive WEEE:concerned
Protection index IP:IP4X
Operating temperature:-25…70 °C
Altitude:2000 m
Air humidity protection:for all climates
Storage/transport temperature:-35…70 °C
  • HND630H
    HND630H MCCB h630 3P 50kA 630A LSI
    HND630H
  • HND630H MCCB h630 3P 50kA 630A LSI
Visitors who viewed this product also viewed the following products
ESC441 Contactor 40A,  4NC,  230V
Contactor 40A, 4NC, 230V
HXC001H Shunt trip Release 24V DC(h250...1000)
Shunt trip Release 24V DC(h250...1000)
HYB001H Collar terminal x250 Al/Cu 3P
Collar terminal x250 Al/Cu 3P
HMD499T MCB 4P 15kA D-125A 6M
MCB 4P 15kA D-125A 6M
HNC040H MCCB h250 3P 50kA 40A LSI
MCCB h250 3P 50kA 40A LSI
HXC042H Motor operator h250 230-240VAC
Motor operator h250 230-240VAC
HXF039H Padlock H1250-H1600
Padlock H1250-H1600
HXF042H Motor operator H1250-H1600 200-230VAC
Motor operator H1250-H1600 200-230VAC
MZ203 Shunt trip 230-415V AC 110-130V DC
Shunt trip 230-415V AC 110-130V DC
HA354 Load break switch 3P 250A
Load break switch 3P 250A
HA356 Load break switch 3P 400A
Load break switch 3P 400A
HA362 Load break switch 3P 1250A
Load break switch 3P 1250A
HA457 Load break switch 4P 400A
Load break switch 4P 400A
NDN250A MCB 2P 10kA/15kA D-50A 2M
MCB 2P 10kA/15kA D-50A 2M
ADA940T RCBO 1P+N 6kA C-40A 30mA A Class
RCBO 1P+N 6kA C-40A 30mA A Class
*All data is subject to errors and technical modifications. All prices are recommended retail prices.