NDN325A

NDN325A MCB 3P 10kA/15kA D-25A 3M

NDN325A
NDN325A MCB 3P 10kA/15kA D-25A 3M
NDN325A MCB 3P 10kA/15kA D-25A 3M

MCB 3P 10kA/15kA D-25A 3M

Cat. Ref.:NDN325A
pc.
EAN No.:

3250614619267

Pack Qty.:4 pc.
ex. GST*:235.74 $ / pc.
inc. GST*:259.31 $ / pc.
Price Group:14230
Technical Characteristics
Neutral position:without neutral
Number of protected poles:3
Number of poles:3 P
Type of pole:3 P
Fixing mode:Din-Rail
Curve:D
Concurrently switching N-neutral:no
Compatible with DIN rail mounting:yes
With fault indicator:no
Top connection alignement for modular devices:Aligned terminal
Bottom connection alignement for modular devices:Aligned terminal
Rated short circuit breaking capacity Icn AC according IEC60898-1:10 kA
Rated operational voltage Ue:400 V
Type of supply voltage:AC
Rated insulation voltage:500 V
Rated impulse withstand voltage:6000 V
Minimum threshold voltage (Ue min):12 V
Rated current:25 A
Rated service breaking capacity Ics AC according IEC 60898-1:7,5 kA
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:10 / 14,4 In
min/maxi threshold value of the DC magnetic operation:15 / 30 In
min/maxi threshold value of the DC thermal operation:1,13 / 1,45 In
Rating current -10°C according to IEC 60947:35,44 A
Rating current -15°C according to IEC 60947:35,87 A
Rating current -20°C according to IEC 60947:36,3 A
Rating current -25°C according to IEC 60947:36,73 A
Rating current -5°C according to IEC 60947:35,01 A
Rating current 0°C according to IEC 60947:34,58 A
Rating current 10°C according to IEC 60947:33,72 A
Rating current 150°C according to IEC 60947:33,29 A
Rating current 20°C according to IEC 60947:32,86 A
Rating current 25°C according to IEC 60947:32,43 A
Rating current 30°C according to IEC 60947:32 A
Rating current 35°C according to IEC 60947:30,25 A
Rating current 40°C according to IEC 60947:28,5 A
Rating current 45°C according to IEC 60947:26,75 A
Rating current 5°C according to IEC 60947:34,15 A
Rating current 50°C according to IEC 60947:25 A
Rating current 55°C according to IEC 60947:23,25 A
Rating current 60°C according to IEC 60947:21,5 A
Rating current 65°C according to IEC 60947:19,75 A
Rating current 70°C according to IEC 60947:18 A
Rated service breaking capacity Ics under 220V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 230V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 240V AC according IEC 60947-2:15 kA
Rated service breaking capacity Ics under 380V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60947-2:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60947-2:7,5 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:10 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:10 kA
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 380V AC according IEC 60898-1:10 kA
Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1:10 kA
Rated service breaking capacity Ics under 220V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 230V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 240V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 380V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 400V AC according IEC 60898-1:7,5 kA
Rated service breaking capacity Ics under 415V AC according IEC 60898-1:7,5 kA
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2:30 kA
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2:15 kA
Rating current -25°C:32,08 A
Rating current -20°C:31,44 A
Rating current -15°C:30,79 A
Rating current -10°C:30,15 A
Rating current -5°C:29,51 A
Rating current 0°C:28,86 A
Rating current 5°C:28,22 A
Rating current 10°C:27,58 A
Rating current 25°C:25,64 A
Rating current 30°C:25 A
Rating current 35°C:24,36 A
Rating current 40°C:23,71 A
Rating current 45°C:23,07 A
Rating current 50°C:22,43 A
Rating current 55°C:21,78 A
Rating current 60°C:21,14 A
Rating current 65°C:20,49 A
Rating current 70°C:19,85 A
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Correction factor of magnetic tripping with 100 Hz:1,1
Correction factor of magnetic tripping with 200 Hz:1,2
Correction factor of magnetic tripping with 400 Hz:1,5
Correction factor of magnetic tripping with 60 Hz:1,1
Frequency:50 to 60 Hz
Maximum power loss per pole according to the product standard:4,5 W
Total power loss under IN:11 W
Power loss per pole at In:3,73 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:83 mm
Width of installed product:52,5 mm
Type of top connection for modular devices:with screw
Tightening torque:2,8Nm
Type of top rail clip for modular devices:NA
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:BIconnect
Top removability for modular devices:yes
Bottom removability for modular devices:yes
Suitable for flush-mounting:yes
360° product mounting position:yes
Connection cross-section at output with screw, for flexible conductor:1 / 25 mm²
Connection cross-section at output with screw, for massive conductor:1 / 35 mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 35 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 25 mm²
Downstream cage clamp delivery status:opened
Upstream cage clamp delivery status:opened
Can be accessorized:yes
With transparent product label holder:yes
Standard text:EN 60898-1, IEC 60947-2
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP20
Operating temperature:-25…70 °C
Degree of pollution according to IEC 60664 / IEC 60947-2:2
Altitude:2000 m
Storage/transport temperature:-25…80 °C
Temperature of calibration:50 °C
  • NDN325A
    NDN325A MCB 3P 10kA/15kA D-25A 3M
    NDN325A
  • NDN325A
    NDN325A MCB 3P 10kA/15kA D-25A 3M
    NDN325A
  • NDN325A MCB 3P 10kA/15kA D-25A 3M
  • NDN325A MCB 3P 10kA/15kA D-25A 3M
Visitors who viewed this product also viewed the following products
HHA030Z MCCB X160 1P 25kA 32A
MCCB X160 1P 25kA 32A
ADA913T RCBO 1P+N 6kA C-13A 30mA A Class
RCBO 1P+N 6kA C-13A 30mA A Class
HA304 LOAD BREAK SWITCH 3P 80A
LOAD BREAK SWITCH 3P 80A
HA408 Load break switch visib.breaking 4P 200A
Load break switch visib.breaking 4P 200A
HEC126H MCCB h250 4P 70kA 125A LSI
MCCB h250 4P 70kA 125A LSI
HEE970H MCCB h1000 3P 70kA 1000A LSI
MCCB h1000 3P 70kA 1000A LSI
HHA064U MCCB h3 x160 TM 4x63A 25kA
MCCB h3 x160 TM 4x63A 25kA
HHA100U MCCB h3 x160 TM 3x100A 25kA
MCCB h3 x160 TM 3x100A 25kA
HHA101U MCCB h3 x160 TM 4x100A 25kA
MCCB h3 x160 TM 4x100A 25kA
HMD180T MCB 1P 15kA D-80A 1.5M
MCB 1P 15kA D-80A 1.5M
HMF399T MCB 3P 10kA C-125A 4.5M
MCB 3P 10kA C-125A 4.5M
HND400H MCCB h630 3P 50kA 400A LSI
MCCB h630 3P 50kA 400A LSI
HNF980H MCCB h1600 3P 50kA 1250A LSI
MCCB h1600 3P 50kA 1250A LSI
HR510 EARTH LEAKAGE RELAY 0.03-10A TIME DELAY
EARTH LEAKAGE RELAY 0.03-10A TIME DELAY
HR704 CIRCULAR SECTION TORROID 140MM
CIRCULAR SECTION TORROID 140MM