HMD390T

HMD390T MCB 3P 15kA D-100A 4.5M

Similar image
(Picture shows HMD399T)

MCB 3P 15kA D-100A 4.5M

Cat. Ref.:HMD390T
pc.
EAN No.:

3250613231408

Pack Qty.:1 pc.
ex. GST*:573.82 $ / pc.
inc. GST*:631.20 $ / pc.
Price Group:14430
Technical Characteristics
Number of protected poles:3
Number of poles:3 P
Type of pole:3 P
Curve:D
Concurrently switching N-neutral:no
Top connection alignement for modular devices:Aligned terminal
Bottom connection alignement for modular devices:Aligned terminal
Rated short circuit breaking capacity Icn AC according IEC60898-1:15 kA
Rated operational voltage Ue:415 V
Type of supply voltage:AC
Frequency:50/60 Hz
Rated insulation voltage:500 V
Rated impulse withstand voltage:6000 V
Rated current:100 A
min/maxi threshold value of the AC thermal operation:1,13 / 1,45 In
Magnetic regulating currrent:10 / 20 In
Rating current 10°C according to IEC 60947:124 A
Rating current 150°C according to IEC 60947:120 A
Rating current 20°C according to IEC 60947:116 A
Rating current 25°C according to IEC 60947:112 A
Rating current 30°C according to IEC 60947:108 A
Rating current 35°C according to IEC 60947:104 A
Rating current 40°C according to IEC 60947:100 A
Rating current 45°C according to IEC 60947:96,6 A
Rating current 50°C according to IEC 60947:93,1 A
Rating current 55°C according to IEC 60947:89,4 A
Rating current 60°C according to IEC 60947:85,6 A
Rating current 65°C according to IEC 60947:81,6 A
Rating current 70°C according to IEC 60947:77,5 A
Breaking capacity on 1 pole for IT 400V NF 60947-2:4,5 kA
Breaking capacity on 1 pole for IT 415V NF 60947-2:4,5 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1:15 kA
Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1:15 kA
Rated service breaking capacity Ics AC according IEC 60947-2:50 %
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2:15 kA
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2:15 kA
Rating current 0°C:124 A
Rating current 5°C:120 A
Rating current 10°C:116 A
Rating current 15°C:112 A
Rating current 20°C:108 A
Rating current 25°C:104 A
Rating current 30°C:100 A
Rating current 35°C:96,6 A
Rating current 40°C:93,1 A
Rating current 45°C:89,4 A
Rating current 50°C:85,6 A
Rating current 55°C:81,6 A
Rating current 60°C:77,5 A
Correction factor of rating current for 2 devices placed side-by-side:1
Correction factor of rating current for 3 devices placed side-by-side:0,95
Correction factor of rating current for 4 and 5 devices placed side-by-side:0,9
Correction factor of rating current for 6 devices placed side-by-side:0,85
Frequency:50 to 60 Hz
Total power loss under IN:21,66 W
Power loss per pole at In:7,98 W
Electric endurance in number of cycles:4000
Number of mechanical operations:20000
Depth of installed product:70 mm
Height of installed product:90 mm
Width of installed product:80 mm
Type of top connection for modular devices:with screw
Tightening torque:3,5 to 5Nm
Type of top rail clip for modular devices:Plastic
Type of bottom rail clip for modular devices:plastic
Type of Bottom Connection for modular devices:with screw
Top removability for modular devices:yes
Bottom removability for modular devices:yes
360° product mounting position:yes
Connection cross-section at output with screw, for flexible conductor:1 / 50 mm²
Connection cross-section at output with screw, for massive conductor:1 / 70 mm²
Connection cross-sect. flexible conductor:50mm²
Connection cross-sect. rigid cable:70mm²
Connection cross-section for rigid conductor, upstream terminals with screws:1 / 70 mm²
Connection cross-section of the access with screws, with flexible conductor:1 / 50 mm²
Connection cross-section of input and output with screws, for massive conductors:1 / 70 mm²
Connection cross section of access and exit with screws, for flexible conductor:1 / 50 mm²
Type of connection:terminal with tightening compensation system
Nominal tightening torque bottom terminal:3,6 Nm
Nominal tightening torque top terminal:3,6 Nm
Standard text:EN 60898-1, IEC 60947-2, AS/NZS 60898-1
European directive WEEE:concerned
Product categories described in the W3E directive 2012/19/EU:Category 5
Protection index IP:IP20
Degree of pollution according to IEC 60664 / IEC 60947-2:3
Altitude:2000 m
Air humidity protection:for all climates
Temperature of calibration:30 °C
  • HMD390T
    HMD390T MCB 3P 15kA D-100A 4.5M
    Similar image
    (Picture shows HMD399T)
  • HMD390T MCB 3P 15kA D-100A 4.5M
Visitors who viewed this product also viewed the following products
HMD499T MCB 4P 15kA D-125A 6M
MCB 4P 15kA D-125A 6M
HR510 EARTH LEAKAGE RELAY 0.03-10A TIME DELAY
EARTH LEAKAGE RELAY 0.03-10A TIME DELAY
HXD040H Motor operator h400-h630 24-48V DC
Motor operator h400-h630 24-48V DC
ADA940T RCBO 1P+N 6kA C-40A 30mA A Class
RCBO 1P+N 6kA C-40A 30mA A Class
HNC040H MCCB h250 3P 50kA 40A LSI
MCCB h250 3P 50kA 40A LSI
HXC042H Motor operator h250 230-240VAC
Motor operator h250 230-240VAC
HXF042H Motor operator H1250-H1600 200-230VAC
Motor operator H1250-H1600 200-230VAC
HYB001H Collar terminal x250 Al/Cu 3P
Collar terminal x250 Al/Cu 3P
NDN163A MCB 1P 10kA/15kA D-63A 1M
MCB 1P 10kA/15kA D-63A 1M
ESC080 Auxiliary contact 6A,  1NO+1NC
Auxiliary contact 6A, 1NO+1NC
ESC441 Contactor 40A,  4NC,  230V
Contactor 40A, 4NC, 230V
HA457 Load break switch 4P 400A
Load break switch 4P 400A
HHA030Z MCCB X160 1P 25kA 32A
MCCB X160 1P 25kA 32A
HHA100U MCCB h3 x160 TM 3x100A 25kA
MCCB h3 x160 TM 3x100A 25kA
HMD180T MCB 1P 15kA D-80A 1.5M
MCB 1P 15kA D-80A 1.5M
*All data is subject to errors and technical modifications. All prices are recommended retail prices.