Technical Characteristics
Bus system:KNX
Precision class:1%
Tariff switch:no
  • Power and energy consumption measurement
  • Total output and total power consumption measurement
  • Reset for partial meter per input
  • Partial and total meter per recording
  • Recording of the total power/consumption figures
  • Tariff switching via 1-byte or 1-bit object
  • flashing counter channel LED (0.1 Wh/pulse x transformer ratio)
  • LC display with illumination
  • with a manual operation button for scrolling through the values
  • with reset button
  • with programming button for adjusting the maximum converter primary current and power supply type
Bus system radio frequent:no
Bus system LON:no
Bus system Powernet:no
Frequency:50/60 Hz
Operating voltage:230/400 V~ +/- 15%
Operating voltage over bus:21…32 V DC
Bus current consumption (data transfer):8 mA
Making current:10 mA
Reference current:5 A
Max. measurement circuit current:5 A
Power consumption measuring element:per phase max. 2,8 VA
Total power loss under IN:2 W
Idle power measurement:YES
Width of rail mounted device (RMD):4 modules
Conductor cross-section (flexible):1…6 mm²
Conductor cross-section (rigid):1,5…10 mm²
Type of connection:direct
  • with connecting terminal for tariff input (HT/NT)
  • with 3-phase mains connection terminal
  • 3 connecting terminals for current transformers
  • with integral bus coupling unit
  • with screw terminals
  • bus connection via connecting terminal
Supported configuration modes:system
Type of counter:other
Differentiation characteristic 2 - Sales:with display
Differentiation characteristic 3 - Sales:with integral bus coupling unit
PTB certified product:1
Protection index IP:IP20
Operating temperature:-10…55 °C
Storage/transport temperature:-25…70 °C