Easy - Relays

10A Relays

TXA608B OUTPUT 8 -FOLD 10A / NE
TXA608B
  • Operating voltage via bus: 21 to 32 V DC
  • Frequency: 50/60 Hz
  • Switching current at cos DC 0.8: max. 10 A
  • 230 V LED bulbs: 12 x 23 W
  • Energy saving lamps: 12 x 23 W
  • 230 V incandescent / halogen light: 1200 W
  • Conventional transformers: 1200 VA
  • Electronic transformers: 1000 W
  • Fluorescent lamps with electronic ballast: 15 x 36 W
  • For switching an independent load per actuator channel or actuation of a blind drive via two actuator channels
  • Any combined operation from drive and switching functions is possible
  • Manual operation can be activated via selector switch, thereby deactivating the KNX function
  • Manual operation per channel via button (single-surface operation)
  • With illuminated programming button
  • Status LED integrated in the manual control button
  • With positioning function for blind and slat position
  • With safety functions eg for wind, rain, alarm
  • Large labelling field
  • For switching various external conductors
  • With integrated bus coupler
  • Bus connection via connection terminal
  • With QuickConnect plug-in terminals
Follow the motor manufacturers' instructions.
For switching independent loads or for controlling drives.
Cat. Ref.  Description ex. GSTinc. GST 
TXA610BOUTPUT 10 -FOLD 10A / NE596.28 $ / pc.655.91 $ / pc.
pc.
TXA608BOUTPUT 8 -FOLD 10A / NE569.18 $ / pc.626.10 $ / pc.
pc.

16A Relays for Capacitive Load

TXA608D OUTPUT 8 -FOLD 16A C-LOAD ADAPTED / NE
TXA608D
  • Operating voltage via bus: 21 to 32 V DC
  • Frequency: 50/60 Hz
  • Switching current at cos φ = 0.8: max. 16A
  • 230 V LED bulbs: 18 x 23 W
  • Energy saving lamps: 18 x 23 W
  • 230 V incandescent / halogen light: 2300 W
  • Conventional transformers: 1600 VA
  • Electronic transformers: 1200 W
  • Fluorescent lamps with electronic ballast: 20 x 36 W
  • For switching an independent load per actuator channel or actuation of a blind drive via two actuator channels
  • Any mixing operation from drive and switching functions is possible
  • Manual operation can be activated via selector switch, thereby deactivating the KNX function
  • With illuminated programming button
  • Status LED integrated in the manual control button
  • With positioning function for blind and slat position
  • With safety functions eg for wind, rain, alarm
  • Large labelling field
  • For switching various external conductors
  • With integrated bus coupler
  • Bus connection via connection terminal
  • With QuickConnect plug-in terminals
 
Follow the motor manufacturers' instructions.
For switching independent loads or for controlling drives.
Cat. Ref.  Description ex. GSTinc. GST 
TXA608DOUTPUT 8 -FOLD 16A C-LOAD ADAPTED / NE596.28 $ / pc.655.91 $ / pc.
pc.
TXA610DOUTPUT 10 -FOLD 16A C-LOAD ADAPTED / NE623.39 $ / pc.685.73 $ / pc.
pc.

10A Relays, 1 Gang, Flush Mounted

TXB601B Output module 1x 10A /230V~, flush,  KNX
TXB601B
  • Operating voltage via bus: 21 to 32 V DC
  • Max. Switching capacity at: 230 V AC
  • Frequency: 50/60 Hz
  • Switching current at cos φ = 0.8: max. 10 A
  • Current consumption KNX: typ. 7 mA
  • Conventional transformers: 600 VA
  • Dimensions (wxhxd): 44x22.5x43mm
  • Status LED integrated in manual control button
  • With illuminated programming key / manual operation key
  • With potential-free NO contact
  • Can be installed in flush-mounted or water-proof junction box
  • Bus connection via prefabricated cable with bus connection terminal
  • With screw terminals
  • With integrated bus coupler
Cat. Ref.  Description ex. GSTinc. GST 
TXB601BOutput module 1x 10A /230V~, flush, KNX189.73 $ / pc.208.70 $ / pc.
pc.